Excellent airtightness for medical and laboratory sealing. Bromobutyl rubber helps limit gas permeation and air ingress, making these stoppers a practical choice for sealing sample bottles, laboratory vessels and anaerobic culture containers.

Product Specifications

Material
Bromobutyl rubber with excellent airtightness and low gas permeability, for sealing medical and laboratory containers, anaerobic culture tubes and culture flasks.
Hardness
30-90 Shore A
Temperature Range
Confirm the selected compound, service temperature, exposure duration and operating medium before ordering.
Colors
Blue, gray. Custom colors can be matched to your Pantone color code.

Custom butyl rubber stoppers are available for medical and laboratory sealing. Share your bottle-neck dimensions and airtightness requirements so we can review the fit, compound and closure design.

Available Sizes

Dimensions are in mm unless otherwise indicated. Custom colors are available to your Pantone color code.

PartNo.ABCDE
RSIIR14.5-19.7-1114.519.71130
RSIIR2.5-5.5-5.32.55.55.320
RSIIR3-4.3-4.534.34.50.80
RSIIR3-7-73772.20
RSIIR3.5-6.5-63.56.5620
RSIIR3.8-7-10.53.8710.51.50
RSIIR3.8-7-73.8771.50
RSIIR4-7.5-647.5620
RSIIR4.5-7.5-64.57.5620
RSIIR4.8-6.8-3.64.86.83.60.90
RSIIR5-8-7-25871.52
RSIIR5-8-7-35871.53
RSIIR5-10-851082.80
RSIIR5.7-11.7-125.711.7126.50
RSIIR6-8-56852.20
RSIIR6.2-8.2-9.66.28.29.63.93.8
RSIIR6.5-8-46.58420
RSIIR6.5-9.5-76.59.5720
RSIIR6.8-8-46.88410
RSIIR7-10-871081.54
RSIIR8-11-881181.54.5
RSIIR8-11-781172.50
RSIIR8.5-12-88.512825
RSIIR8.5-10-68.510620
RSIIR8.6-11-3.38.6113.32.20
RSIIR8.8-11-158.811153.20
RSIIR9-13-8913825.5
RSIIR9-13-9913925
RSIIR10-14-91014926
RSIIR10-12-1010121020
RSIIR10-15-1110151110
RSIIR10.5-12-1010.5121010
RSIIR10.5-13.2-2110.513.22145.7
RSIIR11-15-1011151027
RSIIR11.2-16.7-11.511.216.711.52.54.7
RSIIR12-16-1012161027.5
RSIIR13-17-1013171028
RSIIR13-19.5-71319.573.30
RSIIR14-18-1014181029
RSIIR15-23-1015231046
RSIIR15.3-20-1015.3201036
RSIIR15.5-20-1015.5201036
RSIIR16-24-1016241047
RSIIR17-25-1017251047
RSIIR17.2-20-717.22071.25.8
RSIIR18-26-1018261048
RSIIR19-27-1019271049
RSIIR19.5-25-1019.52510310
RSIIR19.5-26-1019.52610516
RSIIR20-27-10202710315
RSIIR20-28-10202810410
RSIIR21-29-10212910411
RSIIR22-29-10222910412
RSIIR23-33-10233310513
RSIIR24-31-10243110414
RSIIR24.5-30-1024.53010315
RSIIR25-35-10253510515
RSIIR25.4-32-1025.43210316
RSIIR26-33-102633103.516
RSIIR27-34-102734103.517
RSIIR28-35-102835103.518
RSIIR29-36-102936103.519
RSIIR30-40-123040121.520
RSIIR30.3-36-1030.336103.520
RSIIR31.3-37-1031.337103.521
RSIIR33.3-38-1233.338123.522
RSIIR36.3-42-1236.342123.525
RSIIR37.6-43.5-1237.643.5123.526
RSIIR39.3-45-1239.345123.528
RSIIR41.3-48-1241.348123.530
RSIIR43.5-49-1243.549123.533
RSIIR46.3-52-1246.352123.535
RSIIR48.5-54-1248.554123.538
RSIIR51.3-57-1251.357123.540
RSIIR53.6-60-1453.660143.542
RSIIR56.3-62-1256.362123.544
RSIIR58.6-65-1458.665143.547
RSIIR61.3-67-1261.367123.549
RSIIR66.3-72-1266.372123.554
RSIIR68.6-75-1468.675143.557
RSIIR71.3-77-1271.377123.559
RSIIR73.6-80-1473.680143.562
RSIIR76.3-82-1276.382123.564
RSIIR78.6-85-1478.685143.567
RSIIR80-90-12.5809012.55.570
RSIIR82.3-87-1282.38712568
RSIIR86.3-92-1286.392123.574
RSIIR91.3-97-1491.397143.578
RSIIR96.3-102-1496.3102143.583
RSIIR101.5-114-15101.511415585
RSIIR140.5-160-15140.516015100

Can’t find your size? Need a custom part?

Send your bottle-neck dimensions, drawing and airtightness requirements. We’ll help you select a butyl rubber stopper for your medical or laboratory sealing application.

Contact Us

MEASURE · SELECT · INSTALL

Airtight sealing for medical and laboratory containers

Good airtightness is the key benefit of these butyl rubber stoppers. The low gas permeability of bromobutyl rubber helps limit gas exchange, while a correctly matched stopper and bottle neck provide a secure seal. Applications include medical containers, laboratory sample bottles and anaerobic culture vessels. Select the compound and closure to suit the contents, handling and storage conditions.

01 / MEASURE

Start with the bottle-neck drawing

Use these definitions with this page’s drawing and model table. Dimensions are in mm; letters may describe different features in other series.

AStem diameter
The plug body entering the bottle neck. Compare with the neck bore at the intended contact depth.
BHead diameter
The flange across the bottle rim. Check the rim and any cap or retainer dimensions.
CStem length
From the underside of the head to the tip. Check the neck depth and any change in the internal neck profile.
DHead thickness
The thickness above the rim. Include it when reviewing clearance and compression with any closure hardware.
EUnderside recess diameter
The reference drawing shows an underside recess; the table includes both zero and nonzero E values. Obtain the selected stopper section, including recess depth and remaining head thickness.
  1. Identify the vessel. Provide its manufacturer, neck drawing or a sample. Record neck bore, bore tolerance, rim OD, rim shape and usable insertion depth.
  2. Include closure hardware. If a cap or retainer is used, provide its drawing and intended assembly method. Confirm whether it is supplied separately.
  3. Describe the full service cycle. State medium, temperature, duration, pressure or vacuum and any cleaning or sterilization cycle that must be evaluated.

02 / SELECT

Medical, laboratory and anaerobic sealing applications

Medical container sealing

For medical bottles and containers where airtight closure is a priority. Match the stopper to the container and contents, and evaluate the selected compound and sterilization compatibility for the intended medical use.

Laboratory sample and reagent bottles

Seal sample bottles, reagent containers and laboratory vessels to help limit air ingress and gas exchange during handling and storage. Select the compound for the sample or reagent and specify the required storage duration and sealing performance.

Anaerobic culture bottles and tubes

Low gas permeability helps limit oxygen ingress into anaerobic culture bottles, tubes and flasks. Verify airtightness with the complete bottle-and-stopper assembly under the intended culture conditions.

Sampling and repeated access

For workflows that involve needle access, specify the needle type, puncture count and required resealing performance. Evaluate samples after access to confirm that the closure continues to meet your airtightness requirements.

03 / INSTALL

Achieve a secure, airtight bottle closure

Bottle-neck section with a flanged stopper; the rim, neck bore and inserted stem are shown; optional closure hardware is not drawn
Illustrative bottle-neck fit only, showing a solid variant. Actual rim geometry, stopper profile and any cap or retainer must follow the approved assembly drawing. Blue = rubber part; gray = mating component. Schematic, not to scale.

Trial assembly checks

  1. Inspect the mating parts. Check the bottle rim and stopper for damage or contamination. Use the preparation method agreed for the application and selected compound.
  2. Confirm seating. Align the stopper with the neck and use the specified assembly method. Check uniform head seating and clearance to the internal neck profile.
  3. Apply the specified closure. Where hardware is required, use the matched cap or retainer and its approved settings. Head diameter alone does not determine closure compression.
  4. Test the complete cycle. Check retention, leakage or gas ingress before and after the intended treatment or storage. If piercing is specified, include the required access cycles in validation.

Send for a fit review: Medical or laboratory application, bottle-neck and closure drawings, selected RSIIR part number, contents, airtightness requirements, sterilization or treatment cycle, storage duration and material requirements. Add these details to your inquiry.

Need an airtight stopper for your application?

Share your medical or laboratory use, bottle dimensions, sealing requirements and quantity. We'll help you review a suitable butyl rubber stopper and prepare a quote.

Contact Our Team

Prefer email? Contact us at [email protected]

Attach a drawing (optional)

Request a Quote

Tell us about your part, including dimensions, material, quantity, application and any special requirements. Attach a drawing if available to help us prepare your quote.

Contact Our Team

Prefer email? Contact us at [email protected]

Attach a drawing (optional)